涉诈剧本检测接口多次调用成功后再次调用出现报错

问题现象

使用涉诈剧本检测功能时,当多次调用接口成功后,再次调用接口时会出现报错。

报错信息如下:

code:1012500001 message:Internal error.

错误信息日志:

=====================Backtrace========================
#00 pc 00000000006ec4cc /system/lib64/platformsdk/libark_jsruntime.so
#01 pc 00000000006eca40 /system/lib64/platformsdk/libark_jsruntime.so
#02 pc 00000000003244b0 /system/lib64/platformsdk/libark_jsruntime.so
#03 pc 00000000001bc734 /system/lib64/platformsdk/libark_jsruntime.so
#04 pc 00000000001bc1c4 /system/lib64/platformsdk/libark_jsruntime.so
#05 pc 000000000024ec2c /system/lib64/platformsdk/libark_jsruntime.so
#06 pc 00000000005cb424 /system/lib64/platformsdk/libark_jsruntime.so
#07 pc 00000000005a21e0 /system/lib64/platformsdk/libark_jsruntime.so
#08 pc 0000000000057480 /system/lib64/platformsdk/libace_napi.z.so
#09 pc 00000000000067cc /system/lib64/module/hms/security/libbusinessriskintelligentdetection_napi.z.so
#10 pc 00000000000660c0 /system/lib64/platformsdk/libace_napi.z.so
#11 pc 000000000007ee58 /system/lib64/platformsdk/libruntime.z.so

背景知识

涉诈剧本检测:金融支付类应用在用户转账、支付前,通过调用Device Security kit的detectFraudRisk接口,检测用户是否受到欺诈威胁。该接口返回一个风险分,以及涉诈行为的线索,例如,接收到涉诈引导信息、设备有被操控风险等,应用可以根据风险分及线索,进行有效提示或拦截。

问题定位

  1. 根据错误码1012500001信息,分析错误原因可能为接口执行流程中调用系统其它接口出现异常。
  2. 检查nonce值是否符合参数要求:nonce值必须为24至80字节之间。
  3. 更换设备重新执行检测,确认是否由于触发接口使用限制导致报错。
  4. 检查接口的约束与限制,每个应用在每个设备上每天最多可以调用10次,超出限制则会报错。

分析结论

涉诈剧本检测接口存在使用约束与限制,每个应用在每个设备上每天最多可以调用10次。若调用接口达到限制次数后,再次调用接口会出现该报错。

修改建议

根据文档说明,每个应用在每个设备上每天最多可以调用10次此接口,目前最大调用次数无法自定义修改。

若应用处于调测阶段,可以通过以下方案来规避每日最大调用次数的限制: