12100001 Invalid Parameters

Error Message

Invalid Parameter. Error message: messageInfo.

Description

The input parameter is incorrect.

Possible Causes

  1. The value of tokenId is 0.
  2. The permission name is empty or exceeds 256 characters.
  3. The flag value in the permission authorization or revocation request is invalid.
  4. The parameters specified for registering a listener are incorrect.
  5. The specified context does not belong to the current application.
  6. The requested permissions do not belong to the same permission group.
  7. The requested permissions include permissions that are not declared by the application.
  8. The type of the requested global switch is invalid.
  9. The specified permission is not a user_grant permission.
  10. The number of array members exceeds 1024 or all members are invalid.
  11. The start time and end time of the permission usage record to be viewed are invalid.
  12. The specified permission is not declared in the application.

Solution

Check the input parameters and correct them to valid values. For valid values, see the parameter description of the corresponding API in @ohos.abilityAccessCtrl (Program Access Control Management).

12100004 Listener APIs Not Used in Pairs

Error Message

The API is not used in pair with others.

Description

This error code is returned when the APIs are not called in the required pairing relationship, or are repeatedly called before the pairing relationship is released.

Possible Causes

  1. The current API is repeatedly called with the same input parameters before the pairing relationship is released.
  2. One of the listener APIs that must be used in pairs is independently called.

Solution

Check whether the current API is used with its matching API:

Related APIs:

12100005 Listener Overflows

Error Message

The number of listeners exceeds the limit.

Description

The number of listeners exceeds the upper limit.

Possible Causes

The number of registered listeners exceeds the system limit of 200.

Solution

Release unused listeners in a timely manner.

12100007 System Service Not Working Properly

Error Message

Service exception.

Description

The system service is abnormal.

Possible Causes

  1. The permission management service cannot start properly.
  2. Failed to read or write IPC (Inter-Process Communication) data.

Solution

Try again later or restart the device.

12100009 Internal Service Error

Error Message

Common inner error.

Description

This error code is returned when an internal service error or a permission popup error occurs.

Possible Causes

  1. Internal error
    • An internal service error or database error occurs.
  2. Permission popup error
    • The application is in the background and cannot properly bring up the popup.
    • The device is in the locked state and cannot properly display the popup.
    • The popup is not processed in time after being brought up, and the popup process is reclaimed by the system because the application exits. For example, the user clears the application process in the recent tasks screen.

Solution

  1. Internal error
    • Restart the device and try again.
  2. Permission popup error
    • Ensure that the application is in the foreground before initiating the popup request.
    • Make sure the device is unlocked before initiating the permission popup request.
    • Make sure the popup is handled in a timely manner. If the popup process is reclaimed by the system because the application exits, no additional operation is required.
  3. If the problem persists, submit a ticket online with the problem description and log information. Technical support personnel will handle it in a timely manner.

12100010 Pending Request

Error Message

The request already exists.

Description

An unprocessed request exists.

Possible Causes

The last request has not been processed yet.

Solution

Wait until the previous permission request is complete, finish the authorization based on the result returned by the previous request, and then initiate the request again.

12100011 All Requested Permissions Granted

Error Message

All permissions in the permission list have been granted.

Description

All input permissions have been granted.

Possible Causes

All requested permissions have been granted.

Solution

No handling is required. This error code indicates that the requested permission has been granted, and the permission setting popup will not be displayed.

12100012 Not All Permissions Are Rejected by the User

Error Message

The permission list contains the permission that has not been revoked by the user.

Description

Some input permissions have not been denied by the user.

Possible Causes

The requested permissions include the permissions that are not rejected by the user.

Solution

Call requestPermissionsFromUser to request permissions from the user first.

12100013 Global Switch Enabled

Error Message

The specific global switch is already open.

Description

The global switch is enabled.

Possible Causes

The global switch is already turned on.

Solution

No handling is required. This error code indicates that the global switch is already enabled, and the global switch setting popup will not be displayed.

12100014 Unexpected Permission

Error Message

Unexpected permission.

Description

The input permission does not meet the requirements.

Possible Causes

  1. When requestPermissionOnSetting is called to display the permission setting popup again, a permission with the manual_settings authorization mode is passed in.
  2. During authorization or authorization cancellation, the permission of the non-user_grant or manual_settings authorization mode is passed.
  3. When openPermissionOnSetting is called to display the popup for redirecting to the settings page, a permission with a non-manual_settings authorization mode is passed in.

Solution

Check whether the input permission meets the requirements.